“Before
we begin system administrator should take backup of current configuration on all nodes”
powermt display dev=all > before_scan.txt (Backup file)
powermt display - Display high level
Host Bus Adapter (HBA) I/O paths
Scan and configure new LUN
ls /sys/class/scsi_host/ - Command to find
scsi_host value (host0 host1 host2)
echo "- - -" >
/sys/class/scsi_host/host0/scan - Command to rescan the bus
Note : "- - -" indicates all controllers, all channels and all luns
should be scanned and should be executed on all nodes.
powermt config - This command checks for available EMC SAN logical devices and
add those to PowerPath configuration list.
powermt display
powermt save - Save a custom PowerPath
configuration.
If you have many nodes you can export mappings on master node and import the same on other nodes (easy way you can place mapping file on nfs share with is shared across all nodes).
emcpadm
export_mappings -f /tmp/r1-mappings (-f option used for file
location) Master node.
emcpadm import_mappings - f
/tmp/r1-mappings (-f option
used for file location) other nodes.
Once mapping files are
imported on other nodes repeat below commands in sequence on all nodes apart
from master node.
powermt display
ls /sys/class/scsi_host/
echo "- - -" >
/sys/class/scsi_host/host0/scan
powermt display
powermt config
powermt save
powermt display dev=all | egrep -i 'logical|pseudo'